Xem lớn hơn
Graco
Graco Reactor A-25
SKU:CE-GRACO-0038
Technical Specifications
Air-Driven Foam Proportioner – The Reactor A-25 is a Graco-engineered spray foam proportioner that gives you the reliability you expect on the jobsite. It maintains consistent temperature control, even when you’re spraying at maximum flow rates – resulting in better quality foam.
\n
\nAir-Driven Foam Proportioner – The Reactor A-25 is a Graco-engineered spray foam proportioner that gives you the reliability you expect on the jobsite. It maintains consistent temperature control, even when you’re spraying at maximum flow rates – resulting in better quality foam.
\n
\n
\n
-
\n
- Maintains temperature setpoints for better yield \n
- Maintains consistent output pressure for uniform spray pattern \n
- Easy to operate and maintain \n
- Best choice for affordability and durability \n
-
\n
- Spray Polyurethane Foam \n

| Graco Reactor A-25 | \n|
| Maximum Fluid Working Pressure | \n1920 psi | \n
| Maximum Input Pressure to Motor | \n120 psi air | \n
| Pressure Ratio Air | \n16:1 | \n
| Air Inlet | \n1/2 npsm(f) | \n
| Recommended Air Supply Hose Size | \n1/2 in ID minimum | \n
| Air Consumption | \n40 scfm /120 psi, 1.6 gpm | \n
| Recommended Hydraulic Supply Hose Size | \n3/4 in ID minimum | \n
| Recommended Hydraulic Return Hose Size | \n1 in ID minimum | \n
| Fluid Inlets | \n3/4 npt(f) | \n
| Fluid Circulation Ports | \n1/4 npsm(m), with plastic tubing/250 psi maximum | \n
| Maximum Fluid Temperature | \n190° F | \n
| Maximum Output (10 weight oil at ambient temperature) | \n25 lb/min at 75 cycles/min | \n
| Output per cycle (A and B) | \n0.031 gal | \n
| Heated Power (A and B Heaters, no hose) | \n10200 Watts | \n
| Sound Power, per ISO 9614–2 | \n94.7 dB(A) at 1000 psi, 3.0 gpm, 15 cpm | \n
| Sound Pressure, 1 m from equipment | \n81 dB(A) at 1000 psi, 3.0 gpm, 15 cpm | \n
| Wetted Parts | \nAluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene | \n
| Line Voltage Requirement | \n|
| 230V 1 phase and 230V 3 phase units | \n195-264 Vac, 50/60 Hz | \n
| 380V 3 phase units | \n338-457 Vac, 50/60 Hz> | \n
| Fluid Outlets | \n|
| Component A (ISO) | \n#8 JIC (3/4-16 unf), with #5 JIC adapter | \n
| Component B (RES) | \n#10 JIC (7/8-14 unf), with #6 JIC adapter | \n